This manual refers to FW version 3.71 (11/2025)
Description

Description note (mifare)
[Meet panel] Description note (mifare)
NOTE:
Residents can access to their corresponding entrance by passing their authorized Mifare identifier(not available for 7-byte cards).. The door will open and release the lock.
The Mifare identifier data must be added through FERMAX MEET MANAGEMENT software. Maximum 100.000 identifiers.
Introduction to the functions
- Call apartment
- Door opening, relay delay setting
- Connect exit button
- Personalize the voice message for door opening
- Open door alarm
- Sabotage alarm
- Access control using RFID
- Alarm management by access control.
- Operating mode
- Status indicator.
Call an apartment
The visitor presses the call button on the 1W panel; a ringtone will sound, and the monitor will chime. The monitor will display the video, and the visitor can speak after answering; then it will unlock.
Access control via MIFARE (RFID)
Residents can access their designated entrance by swiping an authorized Mifare card. When the card is brought near the reader, the door will open and a voice message will play if access is successful. (Not available for 7-byte cards)
Installation and diagrams
Mounting of the panel
[Placa] Altura de instalación

To ensure an accessible, standardised and user-friendly installation, it is recommended that the highest push-button, key or operating element of the product installed outdoors be positioned at a height of 120 cm above the ground.
This height falls within the range established by regulations in several countries (France, the UK, Singapore, etc.) for accessible mechanisms, which stipulate a height of between 80 and 120 cm. This facilitates use by people with reduced mobility or wheelchair users.
Furthermore, this positioning remains within the standard installation tolerances (±10 cm), allowing it to adapt to the characteristics of the façade and ensuring the system’s correct visibility and functionality.
This approach ensures a convenient, accessible installation that complies with current technical recommendations.
In any case:
|
Installation guide diagram
*Items not included:
1843 Nui 1W Flush Mounting Box
1844 Nui 1W Hood Meet
- Surface box installation:
- Standard

1 - Surface box / 2 - Main module sealing gasket / 3 - Connector area cover / 4 - Main module / 5 - Front cover
- With the visor

1 - Surface box / 2 - Hood sealing gasket / 3 - Hood / 4 - Main module sealing gasket
/ 5 - Connector area cover / 6 - Main module / 7 - Front cover
2. Installation with flush-mount box:
- Standard

1 - Flush-mount box / 2 - Main module sealing gasket / 3 - Connector area cover / 4 - Main module / 5 - Front cover
- With the hood

1 - Flush-mount box / 2 - Visor sealing gasket / 3 - Hood / 4 - Main module sealing gasket
/ 5 - Connector area cover / 6 - Main module / 7 - Front cover
Connector

POWER INPUT: 12V DC power supply for cases where PoE LAN is not available.
OUTPUT: Electric lock control relay output.
- NC: Normally Closed Contact
- NO: Normally open contact
- C: Common
Exit button / Door sensor.
- (EXIT, -) Connections for indoor button
- (NA) Not in use.
- (DS, -) Connection for open door sensor
RS485:
- R485 output for module Ref. 1490
RJ45 Network
- LAN RJ-45 or LAN PoE connection
Basic schemes:

NOTE:
By installing an open door sensor in DS, an alarm sounds on the keypad and at the concierge if the door remains open for 120 seconds.
The panel has an internal tamper button. If the front cover is removed from the central unit, an alarm is triggered on the panel and at the concierge (if there is one).
Operation
1W panel
The associated concierge mode allows you to disable monitoring or NIGHT mode. The visitor presses the call button on the 1W panel, and a ringtone will sound. The monitor will display a 30-second countdown timer while the ringing occurs. The monitor will then display video, and you can speak after answering; it will then unlock.
The associated concierge mode enables monitoring. The visitor presses the call button on the 1W panel, and a ringtone sounds. The monitor displays a 15-second timeout while the call rings. The monitor displays video and allows for conversation after the call is answered. Upon unlocking, the call is transferred to the concierge if the monitor does not answer or the door does not unlock.
The associated concierge mode is DAY, the visitor presses the call button on the 1W panel, the callback tone will be sent, the call will be transferred to the concierge.
The concierge can transfer the call from panel 1W.
Block panel
The panel will call the concierge when the visitor presses the button; the sign will send a special sound if the concierge in NIGHT mode or the general concierge enables ONLY RECEIVE CALLS FROM THE PANEL.
The sign can call the concierge in another way.
The concierge can transfer the call from the lock panel.
General entrance panel
The panel will call the concierge when the visitor presses the button; the panel will send a special sound if the concierge has NIGHT mode.
The panel can call the concierge in another way.
The concierge can transfer the call from the lock panel.
Web browser programming
The 1W Panel an integrated web server that allows you to configure parameters. This web server is accessed using the panel's IP address.
The browser opens with the panel's configured IP address. A screen appears requesting a username and password.
- Default IP address: 10.1.1.2
- Username : admin
- Password : 123456
Device
The following information is displayed: device name, firmware version, MAC address, panel IP address.

General
The GENERAL section allows the configuration of the identification parameters of the Nui 1W panel within the installation.
Allows you to set the date and time.

TYPE : Select the panel identification parameter. There are other related parameters depending on the selected TYPE.
General Entrance Panel
Panel installed at one of the main entrances of a condominium.

[Meet panel] General entrance panel webserver
-
DEVICE NUMBER: Number assigned to the general entrance where this panel is installed (1-9000).
In the case that there is one entrance only, leave the default value 1. - DEVICE TAG: Text to be shown in the monitor and guard unit.
- CONCIERGE: Each concierge can be assigned a concierge number from 9901 to 9998, depending on the facility.
Block Entrance Panel
Panel installed on a single building or on a block of a condominium.

[Meet panel] Block Panel Entrance webserver
- BLOCK: Number assigned to the block where the panel has been installed (1-999). In the case of individual blocks, let the default value: 1.
- DEVICE NUMBER: Number assigned to the block entrance where this panel is installed (1-99). In the case that there is one entrance only, leave the default value. 1.
- DEVICE TAG: Text to be shown in the monitor and guard unit.
- CONCIERGE: Each concierge can be assigned a concierge number from 9901 to 9998, depending on the facility.
1W Panel
For a house or apartment. You can only call an apartment.

[Meet panel] 1 way panel webserver
- BLOCK: Number assigned to the block where the house or apartment belongs (1-999). In the case of individual apartments or houses, leave the default value: 1.
- APARTMENT: Apartment number where this panel is installed. (0001-9899)
- DEVICE NUMBER: Number assigned to this panel (1-9). In the case that there is one panel only, leave the default value 1.
- DEVICE TAG: Text to be shown in the monitor and guard unit.
VIDEO RESOLUTION : To adapt to different types of monitors. The default value is 640×480.
PANEL VOLUME: Select a value between 1 and 5 to adjust the panel's audio output. The default setting is 4.
This volume level affects speech synthesis and notification tones.
The conversation volume adjusts automatically.
[Meet panel] VOICE SYNTH general webserver
VOICE SYNTH:Enables or disables the speech when door lock is released. If the speech is disabled, no speech in the panel will sound when the lock is released.
[Meet panel] Language general webserver
LANGUAGE: Select the desired language in the dropdown options.
Default option is ENGLISH.
Refresh the webpage after changing the language
If select CUSTOM, the custom language will available if the custom language file be imported, the default language (selected language in FROM ) will available if no custom language file is be imported.
The panel will reboot if the custom language be imported or be deleted
The language file include KEY, DEFAULT STRING, CUSTOM STRING and REMARK.
Do not modify KEY, DEFAULT STRING and REMARK.
The language in default string of exported language file base on selected language in FROM.
CUSTOM STRING is new description, empty or *, the default string still is available if the custom string is empty, do not display anything if the custom string is *.
REMARK prompt that some characters do not require translation.
The VOICE PROMPT file is available when the CUSTOM is be selected, otherwise the voice prompt is default.
- DATE FORMAT: Format to show the date information in the screen.
- DATE: Setting date manually (See NOTE below).
- TIME: Setting time manually (See NOTE below).
- TIME ZONE: Setting the time zone of panel. Select local time zone and save.
- DAYLIGHT SAVING TIME: Shall be enabled for DST periods and disabled for wintertime.
If the project does not have management software, the installer can manually configure the date, time, and time zone. If the project does have management software, the panel's date and time will automatically synchronize with it. If the panel has internet access, it will also synchronize with the internet time server.
NOTE:
1. THE TIME ZONE is only usable when the time is taken automatically from the internet or from the FERMAX MANAGEMENT SOFTWARE.
2. It is not possible to save the date or time after a power outage, but the time zone and date format can be saved.
3. The web server will display “TOTAL: XXX RECORDS IMPORTED” when the language file is imported.
Network configuration
[Meet panel] Network configuration webserver
IP: IP address to be assigned to this panel.
MASK: Subnet mask corresponding to the LAN
GATEWAY: LAN gateway
DNS: DNS server address. In case of doubt, we recommend using the default value 8.8.8.8.
SOFTWARE IP: IP address of the PC where the MEET Management Software is installed (if any).
SOFTWARE PIN: PIN ACCESS code for the Management Software control. The default setting is 123456. Indicate the corresponding parameters and click on SAVE to confirm.
NTP SERVER IP: The date and time will synchronous with the NTP server If the panel has access to internet, the default NTP server is pool.ntp.org.
NOTE:
The MEET system uses static IP addressing. This ensures that each device has a unique IP address in the same installation.
If a device has an IP address already assigned to another device on the network, an "IP CONFLICT" prompt will appear in the panel screen, along with the MAC of the conflicting device.
Both devices will not work properly until this issue is resolved.
If a device has an IP address already assigned to another device on the network,
Both devices will not function properly until this problem is resolved.
Access
DOOR RELAY TIME: Time the door opener relay remains active (1-9s optional).
[Meet panel] Open door delay acces webserver
OPEN DOOR DELAY: The time that the open-door command has be sent and the relay is not activated. The relay will active after the DOOR DELAY TIME be set, Open door relay is useful when the door is not close the panel. (option 0-9 s)
ADMINISTRATOR CARD: Registered administrator/master card ID for registering additional proximity cards. This option is useful when MEET management software is not available.
If you do not have management software, enter 0000 if you do not know the administrator card ID. The first MIFARE proximity card detected by the reader will act as the administrator/main card. Resident cards can be added later.
To program user cards, present the previously created administrator/master card to the card reader. The panel will enter card programming mode. All cards presented from this point forward will be automatically updated on the panel and can be used to open the door.
If there are no more cards to program, after two minutes the panel will exit programming mode.
It is not possible to deactivate programmed cards using this method. Use the MEET FERMAX management software to take advantage of all operational features.
DISARM BY CARD: When a user card that has been programmed and previously assigned to a monitor is presented to the reader, the alarm system of the corresponding department will change to HOME mode.
ACCESS PIN: No function.

IP Camera
[Meet panel] IP Camera webserver
The monitor can switch to IP CCTV camera video during a conversation. This function allows to configure IP CCTV cameras using RTSP protocol to be displayed as an auxiliary camera to provide different view angles from the door or related areas.

NUMBER OF CAMS: IP camera Number. Up to 4 different cameras.
- CAMERA 1, 2, 3 and 4: IP camera name.
-
URL: -> rtsp://user:password@Ip_adress_of_camera
user: password -> for cameras that require a username and password for connection.
Depending on the brand/model of camera, other URL different than the one above would be required. Check the IP camera technical documentation.
MAIN VIDEO STREAM: Main video stream can from panel camera or from IP camera.
⚠️ The use of video surveillance cameras may be subject to the legislation of the country where they are installed. Ensure that current legislation on personal data protection is complied with.
SIP
This option allows you to configure the 1W panel to use SIP functions, such as forwarding calls to your smartphone using the FERMAX MEET ME app, or to allow the panel to work with third-party SIP systems or terminals that use the SIP protocol instead of the FERMAX MEET protocol.
ENABLE SIP: Select this checkbox to enable SIP features.
SIP STATUS SEARCH: This button appears when the SIP function is enabled, it displays SIP REGISTERED if the panel was successfully registered or SIP REGISTRATION FAILED if the panel was unsuccessfully registered.
SIP SERVER: Enter the SIP server address. Format -> sip:IP_SERVER
DOMAIN: SIP server domain or IP address.
STUN IP: SIP server domain.
STUN PORT: Used for configuring installations based on Internet SIP servers. It is usually port 5060. Consult your network or SIP server administrator.
TRANSPORT: Options: UDP, TCP, and TLS. Default: UDP. The UDP port is 5060. If no port is specified, the default port is 5060. If no port is specified, sip:sip.fermax.com. The UDP port is 5223 and the TLS port is 4443.
SIP USERNAME, SIP PASSWORD: Indicates the username and password with which this terminal is programmed on the SIP server.
CONVERSATION, BELL TIME : No function.
NOTE: When the panel is used as a SIP device, use speed dial to call SIP devices or receive calls from other SIP devices; the SIP function must be enabled.

SIP call
[Meet panel] SIP Call webserver
This option allows to generate calls to smartphone devices in the cases where it is not a MEET monitor associated in the installation. A FERMAX MEET ME licence Ref. 1496 is required for each apartment
The call can be received in 8 smartphones simultaneously.
Furthermore, it is also possible, to generate simultaneous calls to several devices MEET and/or third-party SIP devices as well, using SIP protocol instead of FERMAX MEET protocol.
A .CSV file containing the associated number and the information of the diverted device or devices must be updated in the panel.
SIP DIVERT MODE: This function is available for the device of sip call list. Please refer to SIP section for further details.
- PARALLEL CALL: When the panel calls the resident, the monitor and the call divert APP in sip call list rings at the same time. Once a terminal answers, the call in the other one stops ringing.
- SEQUENTIAL CALL: When the panel calls the resident, the monitor will ring 30s. If no answer, the call will be diverted to MEET ME APP or other associated devices.
APARTMENT: The panel calls the resident.
NUMBER: The monitor, the call divert APP and the SIP device.
DELETE: Delete Apartment and number.

Advanced
Speed dial is associated with a monitor, a concierge or a SIP terminal.
SPEED DIAL: Activates or deactivates the speed dial function.
NOTE: Speed dial works when the panel is a general panel or a block panel; the panel does not call the concierge.
URL : If calling the MEET system device, URL: sip: SIP account @ IP address of the MEET device (the SIP account is optional). If calling the SIP device, URL: sip: SIP account @ IP address of the SIP server.
ONU (GPON): Enables or disables the SIP penetration firewall function.

PIN code
[Meet panel] PINCODE webserver
It allows you to change the INSTALLER PIN code, to access the installation configuration parameters through a web browser.

Enter the current code, the new pin and confirm it.
The new password can have alphanumeric characters and has no limit on its length.
Finally, select SAVE.
NOTE:
Make a note of the new PIN at your convenience. If you lose or forget your PIN, you should contact FERMAX's Technical Department to receive instructions regarding its recovery. All settings programmed into the panel will be lost after recovery.
Management
[Meet panel] Management webserver
Use this functionality to import, export configuration file, reboot remotely the panel, return it to factory settings, or log out webserver

CONFIGURATION FILE: Allow installers to save a backup of its configuration via export button, later apply that previously exported file via import button to the same or a different panel with same version.
- The exported configuration file do not include imported picture, the language file ,directory file and sip call file.
- Press import button, the pop will appear.

- Press SKIP, the general settings from be imported configuration file, if the general settings is different with imported configuration file, modify general settings and press OK.
RESTORE FACTORY SETTINGS: All factory settings will be restored. The IP address will be changed to the default: 10.1.1.2.
[Meet panel] Management reboot + log out webserver
REBOOT DEVICE: The panel will automatically turn off and start up keeping all the programming parameters.
When resetting, the device will lose connection with the PC. Refresh the website after about 60 seconds to resume the connection.
LOG OUT: Press OK and log out webserver, appear interface of log in.
Firmware updates
[MEET panel] Firmware updates
Sometimes it may be necessary or convenient to update a new firmware version because improvements or corrections have been incorporated into its operation.
FERMAX's Technical Department periodically informs (through Communications, Technical Bulletins, etc.) about the release of a new firmware update, as well as the improvements incorporated.
Contact the FERMAX Technical Department if you wish to receive the corresponding update file.
The firmware update is performed via the FERMAX MEET System Upgrading Tool V01.00.exe. The procedure for updating the firmware with the corresponding update file is as follows:
- Start the FERMAX MEET System Upgrading Tool v1.00. exe.

-
Click on “…” button and browse the PC to find the corresponding .IMG update file.
Up to 3 .IMG files can be selected at the same time (for the case of the update has more than unique .IMG file). - Indicate the IP Range of the panels.
- Click on “Start”.
The new firmware will be installed, and the panel will restart automatically.
RTSP transmission from an external panel
[Meet panel] RTSP STREAMING FROM OUTDOOR PANEL
Using an external element (PC/Tablet/Smartphone) connected to the network makes it possible to access the panel’s built-in camera via RTSP protocol with the following address:
rtsp://admin:password@Panel_IP:8554/ch01
admin: admin
password: 123456 (Default), if it has been changed we will use the current password.
Panel_IP: Current IP adress of the panel.
It is possible to access using VLC as in the image below:

Regulation
FERMAX ELECTRÓNICA, SAU declares that this product meets the requirements of:
Directive 2014/53/EU “Radiofrequency equipment”
https://www.fermax.com/spain/documentacion/documentacion-tecnica?type=declarations_of_conformity
Radio frequency module:
• Frequency: 13.56MHz / Maximum power: 0.825W
Download Article
Table of Contents