This manual refers to FW version 3.71 (11/2025)
Description

Description note (mifare)
Introduction to the functions
- Call apartment
- Door opening, relay delay setting
- Connect exit button
- Personalize the voice message for door opening
- Open door alarm
- Sabotage alarm
- Access control using RFID
- Alarm management by access control.
- Operating mode
- Status indicator.
Call an apartment
The visitor presses the call button on the 1W panel; a ringtone will sound, and the monitor will chime. The monitor will display the video, and the visitor can speak after answering; then it will unlock.
Access control via MIFARE (RFID)
Residents can access their designated entrance by swiping an authorized Mifare card. When the card is brought near the reader, the door will open and a voice message will play if access is successful. (Not available for 7-byte cards)
Installation and diagrams
Mounting of the panel
Installation guide diagram
*Items not included:
1843 Nui 1W Flush Mounting Box
1844 Nui 1W Hood Meet
- Surface box installation:
- Standard

1 - Surface box / 2 - Main module sealing gasket / 3 - Connector area cover / 4 - Main module / 5 - Front cover
- With the visor

1 - Surface box / 2 - Hood sealing gasket / 3 - Hood / 4 - Main module sealing gasket
/ 5 - Connector area cover / 6 - Main module / 7 - Front cover
2. Installation with flush-mount box:
- Standard

1 - Flush-mount box / 2 - Main module sealing gasket / 3 - Connector area cover / 4 - Main module / 5 - Front cover
- With the hood

1 - Flush-mount box / 2 - Visor sealing gasket / 3 - Hood / 4 - Main module sealing gasket
/ 5 - Connector area cover / 6 - Main module / 7 - Front cover
Connector

POWER INPUT: 12V DC power supply for cases where PoE LAN is not available.
OUTPUT: Electric lock control relay output.
- NC: Normally Closed Contact
- NO: Normally open contact
- C: Common
Exit button / Door sensor.
- (EXIT, -) Connections for indoor button
- (NA) Not in use.
- (DS, -) Connection for open door sensor
RS485:
- R485 output for module Ref. 1490
RJ45 Network
- LAN RJ-45 or LAN PoE connection
Basic schemes:

NOTE:
By installing an open door sensor in DS, an alarm sounds on the keypad and at the concierge if the door remains open for 120 seconds.
The panel has an internal tamper button. If the front cover is removed from the central unit, an alarm is triggered on the panel and at the concierge (if there is one).
Operation
1W panel
The associated concierge mode allows you to disable monitoring or NIGHT mode. The visitor presses the call button on the 1W panel, and a ringtone will sound. The monitor will display a 30-second countdown timer while the ringing occurs. The monitor will then display video, and you can speak after answering; it will then unlock.
The associated concierge mode enables monitoring. The visitor presses the call button on the 1W panel, and a ringtone sounds. The monitor displays a 15-second timeout while the call rings. The monitor displays video and allows for conversation after the call is answered. Upon unlocking, the call is transferred to the concierge if the monitor does not answer or the door does not unlock.
The associated concierge mode is DAY, the visitor presses the call button on the 1W panel, the callback tone will be sent, the call will be transferred to the concierge.
The concierge can transfer the call from panel 1W.
Block panel
The panel will call the concierge when the visitor presses the button; the sign will send a special sound if the concierge in NIGHT mode or the general concierge enables ONLY RECEIVE CALLS FROM THE PANEL.
The sign can call the concierge in another way.
The concierge can transfer the call from the lock panel.
General entrance panel
The panel will call the concierge when the visitor presses the button; the panel will send a special sound if the concierge has NIGHT mode.
The panel can call the concierge in another way.
The concierge can transfer the call from the lock panel.
Web browser programming
The 1W Panel an integrated web server that allows you to configure parameters. This web server is accessed using the panel's IP address.
The browser opens with the panel's configured IP address. A screen appears requesting a username and password.
- Default IP address: 10.1.1.2
- Username : admin
- Password : 123456
Device
The following information is displayed: device name, firmware version, MAC address, panel IP address.

General
The GENERAL section allows the configuration of the identification parameters of the Nui 1W panel within the installation.
Allows you to set the date and time.

TYPE : Select the panel identification parameter. There are other related parameters depending on the selected TYPE.
General Entrance Panel
Panel installed at one of the main entrances of a condominium.

- CONCIERGE: Each concierge can be assigned a concierge number from 9901 to 9998, depending on the facility.
Block Entrance Panel
Panel installed on a single building or on a block of a condominium.

- CONCIERGE: Each concierge can be assigned a concierge number from 9901 to 9998, depending on the facility.
1W Panel
For a house or apartment. You can only call an apartment.

VIDEO RESOLUTION : To adapt to different types of monitors. The default value is 640×480.
PANEL VOLUME: Select a value between 1 and 5 to adjust the panel's audio output. The default setting is 4.
This volume level affects speech synthesis and notification tones.
The conversation volume adjusts automatically.
If the project does not have management software, the installer can manually configure the date, time, and time zone. If the project does have management software, the panel's date and time will automatically synchronize with it. If the panel has internet access, it will also synchronize with the internet time server.
NOTE:
1. THE TIME ZONE is only usable when the time is taken automatically from the internet or from the FERMAX MANAGEMENT SOFTWARE.
2. It is not possible to save the date or time after a power outage, but the time zone and date format can be saved.
3. The web server will display “TOTAL: XXX RECORDS IMPORTED” when the language file is imported.
Network configuration
If a device has an IP address already assigned to another device on the network,
Both devices will not function properly until this problem is resolved.
Access
DOOR RELAY TIME: Time the door opener relay remains active (1-9s optional).
ADMINISTRATOR CARD: Registered administrator/master card ID for registering additional proximity cards. This option is useful when MEET management software is not available.
If you do not have management software, enter 0000 if you do not know the administrator card ID. The first MIFARE proximity card detected by the reader will act as the administrator/main card. Resident cards can be added later.
To program user cards, present the previously created administrator/master card to the card reader. The panel will enter card programming mode. All cards presented from this point forward will be automatically updated on the panel and can be used to open the door.
If there are no more cards to program, after two minutes the panel will exit programming mode.
It is not possible to deactivate programmed cards using this method. Use the MEET FERMAX management software to take advantage of all operational features.
DISARM BY CARD: When a user card that has been programmed and previously assigned to a monitor is presented to the reader, the alarm system of the corresponding department will change to HOME mode.
ACCESS PIN: No function.

IP Camera
SIP
This option allows you to configure the 1W panel to use SIP functions, such as forwarding calls to your smartphone using the FERMAX MEET ME app, or to allow the panel to work with third-party SIP systems or terminals that use the SIP protocol instead of the FERMAX MEET protocol.
ENABLE SIP: Select this checkbox to enable SIP features.
SIP STATUS SEARCH: This button appears when the SIP function is enabled, it displays SIP REGISTERED if the panel was successfully registered or SIP REGISTRATION FAILED if the panel was unsuccessfully registered.
SIP SERVER: Enter the SIP server address. Format -> sip:IP_SERVER
DOMAIN: SIP server domain or IP address.
STUN IP: SIP server domain.
STUN PORT: Used for configuring installations based on Internet SIP servers. It is usually port 5060. Consult your network or SIP server administrator.
TRANSPORT: Options: UDP, TCP, and TLS. Default: UDP. The UDP port is 5060. If no port is specified, the default port is 5060. If no port is specified, sip:sip.fermax.com. The UDP port is 5223 and the TLS port is 4443.
SIP USERNAME, SIP PASSWORD: Indicates the username and password with which this terminal is programmed on the SIP server.
CONVERSATION, BELL TIME : No function.
NOTE: When the panel is used as a SIP device, use speed dial to call SIP devices or receive calls from other SIP devices; the SIP function must be enabled.

SIP call
APARTMENT: The panel calls the resident.
NUMBER: The monitor, the call divert APP and the SIP device.
DELETE: Delete Apartment and number.

Advanced
Speed dial is associated with a monitor, a concierge or a SIP terminal.
SPEED DIAL: Activates or deactivates the speed dial function.
NOTE: Speed dial works when the panel is a general panel or a block panel; the panel does not call the concierge.
URL : If calling the MEET system device, URL: sip: SIP account @ IP address of the MEET device (the SIP account is optional). If calling the SIP device, URL: sip: SIP account @ IP address of the SIP server.
ONU (GPON): Enables or disables the SIP penetration firewall function.

PIN code
Management
RESTORE FACTORY SETTINGS: All factory settings will be restored. The IP address will be changed to the default: 10.1.1.2.
Firmware updates
RTSP transmission from an external panel
Regulation
FERMAX ELECTRÓNICA, SAU declares that this product meets the requirements of:
Directive 2014/53/EU “Radiofrequency equipment”
https://www.fermax.com/spain/documentacion/documentacion-tecnica?type=declarations_of_conformity
Radio frequency module:
• Frequency: 13.56MHz / Maximum power: 0.825W
Download Article
Table of Contents