970137 Installer manual Milo 1W Panel

Written by Tecnico Internacional

Updated at December 23rd, 2025

  • MEET
    Monitors Panels Guard Unit Others
  • DUOX
    Monitors
+ More

Description

 

Functions introduccion

  • Call apartment
  • Open door, relay delay settings
  • Connect exit button
  • Speech message for release lock 
  • Door opened alarm 
  • Tamper alarm 
  • Alarm management by access control (only panel with proximity reader)
  • Work mode

Call apartment

Visitor push the pushbutton for calling in the 1W Panel, the ring back tone will be sent, meanwhile the monitor will ring. The monitor will show video and can conversation after answer, then release lock.

Web browser programming

The 1W panel has an integrated web server, which allows to configure the parameters. This web server is accessed via the panel’s IP address.

The browser opens with the configured IP address of the panel. A screen opens requesting a username and password.

  • Default IP: 10.1.1.2
  • Username: admin
  • Password: 123456

Device

The following information is displayed: device name, firmware version, MAC address, IP address about the panel.

 
 

General

The section GENERAL allows the configuration of the identification parameters of the 1W MILO panel within the installation.

It allows time-date configuration.

TYPE: Select the identification parameter of the panel. There are some other parameters related, depending on TYPE selection.

General entrance panel

Panel installed in one of the main entrances to a condominium.

  • CONGIERGE: The number of concierges can be assigned to each concierge from 9901 to 9998, depending on the installation.
 
 

Block panel entrance

Panel installed in a single building or in a block of a condominium.

  • CONGIERGE: The number of concierges can be assigned to each concierge from 9901 to 9998, depending on the installation.
 
 

1 Way panel

For a single house or apartment. It can only call to a unique apartment.

VIDEO RESOLUTION: To fit the different types of monitors. The default value 640×480 

PANEL VOLUME: Select a value between 1 and 5 to adjust the panel's audio output. The default setting is 4.
This volume level affects the voice synthesis, and notification tones.
Conversation volumen is autoadjusted. 

If the project has no management software the installer can set date, time and time zone manually. If the project has management software, the date and time of panel will synchronizes automatically with the management software. If the panel has access to internet, the date and time of panel will also synchronize with internet time server.

NOTE: 
1.TIME ZONE is usable only when the time is automatically taken from internet or FERMAX MANAGEMENT SOFTWARE. 
2. Date and time can’t be saved after power loss, the time zone and date format can be saved.
3. The webserver will show “TOTAL: XXX RECORD(S) IMPORTED” when the language file is be imported.

 
 
 
 

Network configuration

If a device has an IP address already assigned to another device on the network,           
Both devices will not work properly until this issue is resolved.

 
 

Access

DOOR RELAY TIME: Time for lock-release relay remains active (1-9s optional).Time for lock-release relay remains active (1-9s optional).

ADMIN CARD: Admin/master card ID registered to enrol additional prox cards. This option is useful when there is not MEET MAGEMENT SOFTWARE available. 

When there is no management software, enter 0000 if you do not know the ID of the admin card. The first MIFARE prox card detected by the reader will act as admin/master card. The card of the residents can be added afterwards. 

To program user cards, present the admin/master card previously created on the card reader. The panel will enter in cards program mode. All the cards presented from now on will automatically updated in the panel and may be used to open the door. 

If there are not more cards to program, after two minutes the panel will exit program mode. 

There is not possible to deregister cards programmed by this method. Use the FERMAX MEET MANAGEMENT SOFTWARE for full operational possibilities.

DISARM BY CARD:When an already programmed user card is presented to the reader, and it has been previously assigned to a monitor, the alarm system of the corresponding apartment will change to HOME mode.

ACCESS PIN: No function.

 
 

IP Camera

 
 

SIP

This option allows to configure 1W panel to use SIP functions, such us call divert to smartphone using the FERMAX MEET ME APP or allows the panel to operate with a third-party SIP systems or terminals using SIP protocol instead of FERMAX MEET protocol.

ENABLE SIP: Select this box to enable SIP functions.

SEARCH SIP STATUS: this button appears when enabling SIP function, shows SIP REGISTERED if the panel register successfully or SIP REGISTER FAILED if the panel register unsuccessfully.

SIP SERVER: Indicate the sip SERVER address. Format -> sip: IP_SERVER

DOMAIN: domain of the SIP server or IP address. 

STUN IP: domain of the SIP server. 

STUN PORT: Used for the configuration of Internet SIP server-based installations. It is usually port 5060. Check with your network or SIP server administrator.

TRANSPORT: UDP, TCP, TLS options. Default UDP, the No. port of UDP is 5060, the default port is 5060 if no port at the back sip:sip.fermax.com, the No. port of UDP is 5223, the No. port of TLS is 4443

SIP USER, SIP PASSWORD: Indicate the user and password that this terminal is programmed in the SIP server.

CONVERSATION, RING TIME: No function.

NOTE: When the panel is used as a sip device, use quick dial to call SIP devices or receive calling of other SIP devices, SIP function must be enabled.

 
 

SIP Call

APARTMET: The panel calls the resident.

NUMBER: The monitor, the call divert APP and sip device.

DELETE: Delete Apartment and number.

 
 

Advanced

Quick dial is associated a monitor, guard unit or sip terminal.

QUICK DIAL: Enable or disable quick dial function.

NOTE: The quick dial work when the panel is general panel or block panel, the panel do not call concierge.

URL: If call device of MEET system, URL: sip: sip account @ IP address of MEET device, the sip account is optional. If call SIP device, URL: sip: sip account @ IP address of sip server

ONU (GPON): Enable or disable the SIP penetration firewall function.

 
 

Pincode

 
 

Management

RESTORE FACTORY SETTINGS: All the settings are restored to the factory settings. The IP address will be changed to the default IP: 10.1.1.2.

 
 

Operation

1W Panel

The mode of associate concierge is to disable Monitoring or NIGHT, Visitor push the pushbutton for calling in the 1W Panel, the ring back tone will be sent, countdown time in the monitor from 30s meanwhile the monitor will ring. The monitor will show video and can conversation after answer, then release lock.

The mode of associate concierge is to enable Monitoring, Visitor push the pushbutton for calling in the 1W Panel, the ring back tone will be sent, countdown time in the monitor from 15s meanwhile the monitor will ring. The monitor will show video and can conversation after answer, then release lock, the calling will transfer to concierge if the monitor doesn’t answer or doesn’t release lock.

The mode of associate concierge is DAY, Visitor push the pushbutton for calling in the 1W Panel, the ring back tone will be sent, the call will transfer to concierge.

The Concierge can transfer the call from 1W panel.

 
 

Block panel

The panel will call concierge when the visitor pushes the pushbutton, the panel send special sound if the concierge with NIGHT mode or general concierge enables ONLY RECEIVE.G.E. PANESL CALLS.
The panel can call concierge with other mode.
The Concierge can transfer the call from block panel.

 
 

General entrance panel

The panel will call concierge when the visitor pushes the pushbutton, the panel send special sound if the concierge with NIGHT mode.
The panel can call concierge with other mode.
The Concierge can transfer the call from block panel.

 
 

Installation and diagrams

Flush box installation

 
 

Installation guide diagram

  1. Flush installar
  2. Base flush box depth adjustment hook.
  3. The upper part of the panel is stuck in, then move the panel to the flush box.
  4. Move the slider of the panel and fix the two screws, when installing, pay attention to the reservation of the 1.7CM space around the door to move the slide cover.
     
 
 

Connector


The 1W PANEL is connected to the installation by means of connectors: Ethernet for LAN connection and MOLEX type connectors for other connections (power supply, RS-485, etc.). A bag containing the corresponding female connectors with their cables comes with the panel.
 

POWER INPUT: 12 Vdc power supply for the cases where no LAN PoE is available.

OUTPUT: Electric lock control relay output.

  • NC: Normally closed contact
  • NO: Normally opened contact
  • C: Common

Exit Button / Door Sensor. 

  • (EXIT, -) Connections for indoor button 
  • (DS, -) Connection for door opened sensor

RJ 45 Network

  • RJ-45 LAN or LAN PoE connection

NOTE:
Installing a door open sensor in DS, an alarm sounds in the panel and concierge if the door remains opened during 120s.
The panel has an internal tamper button. If the panel is separated from the wall, an alarm is triggered in the panel, concierge (if exists).

 
 

Tamper installation

 
 

 

Firmware updates

RTSP Streaming from outdoor panel 

Regulation

FERMAX ELECTRÓNICA, S.A.U. declares that this product complies with the requirements of:
RED 2014/53/EU Directive “Radio frequency equipment”

https://www.fermax.com/intl/en/pro/documents/technical-documentation/DT-13-declarations-of-conformity.html

Radio frequency module:
• Frecuencia: 13.56MHz / Potencia máxima: 2,45mW

 

 

lamp small

Download Article

Table of Contents

Description Functions introduccion Call apartment Web browser programming Device General Network configuration Access IP Camera SIP SIP Call Advanced Pincode Management Operation 1W Panel Block panel General entrance panel Installation and diagrams Firmware updates RTSP Streaming from outdoor panel Regulation

Related Articles

  • 970190 Marine/Milo panel installation manual
  • 970162 Kin Panel installation
  • 970379 Nui 1W Panel

For more information, visit www.fermax.com
Contact: tec@fermax.com www.fermax.com/contact

Fermax logo

FERMAX ELECTRONICA S.A.U

Avenida Tres Cruces, 133
46017 Valencia, Spain

Expand