The Auto-on function is activated from the CAMERA icon in the Main Menu.
The preview times, in total (regardless of whether the camera is changed), from the start of the auto-on or audio connection, are:
- No audio (30 s).
- In conversation (90 s).
If the selected panel/camera is not available or is busy, the monitor:

- Will emit a sound alert and return to standby.
- At the same time, it will display an icon on the screen for 3 s indicating: NOT AVAILABLE.

- To do this, press one of the multifunction buttons 1-4 with the screen in standby.
- Select the icon with the multifunction button 1.
- During the 15 seconds after finishing the conversation with a panel, when doing the auto-on, you will be able to have a conversation with that same panel, whichever it is. This is indicated on the screen as the panel Redialed (R).

Press the multifunction button 1 to turn off the camera.
- Press the multifunction button 2 to activate additional function 1 (F1).
- Press the multifunction button 3 to access call settings.
- Press the multifunction button 4 to toggle between general input, block input 0, and block input 1 (panels or cameras).

- Press the conversation (1) button to establish or end the audio conversation with the street panel.
- Press the door opener (2) button to activate the main door opener.
- During the conversation, press the multifunction button 1 to mute the microphone.
Notes:
- If the monitor is not programmed with an address, it will not be able to perform the auto-on function.
- If a call has been made from one panel to another residence and is within the waiting time for them to answer (30 seconds), communication (auto-on) with that panel will not be possible.
- If the line is busy or there is another terminal in the same residence in conversation, the auto-on will also not be possible.
- If the second channel or a dual-channel monitor is also busy, it will not allow connection with the selected panel/camera.
- In all cases where connection is not possible, the icon NOT AVAILABLE will be displayed on the screen and a sound alert will be emitted. After that, the monitor will return to standby after 3 s.